Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Odovtos (En línea) ; 24(3)dic. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1406161

ABSTRACT

Abstract Using a bur multiple times to prepare dental structure may produce a smoother final surface on dentin than a new one. This superficial roughness may affect adhesion with resin-based materials by modifying the substrates' characteristics. The aim of this study was to evaluate the effect of multiple uses of diamond burs on dentin's superficial microroughness and bond strength with resin composite when using a self-etch adhesive. Diamond dental burs were used to simulate a preparation (dentin flat surface) on extracted third molars. Samples were distributed into groups according to burs' number of previous uses as follows: 0, 1, 5 and 10. Scanning electron microscopy images at 70x, 350x, and 1000x were used to illustrate burs' deformation. Each specimen's dentin microroughness was measured three times to compare between experimental groups and the micro-shear bond strength test (n=15) was performed for the 0 and 10 uses groups using a universal adhesive in a self- etching mode. Diamond crystals wear and dislodgements were evident among groups where the burs were used more times. As the number of uses increased the mean microroughness of the dentin surface decreased with significant differences between the 0 and 10 uses groups. No statistical differences between experimental groups resulted from bond strength tests. When using a universal adhesive in a self-etching mode, the number of previous uses of a diamond bur seems to have no significant effect on dentin/resin composite bond strength.


Resumen El uso de una fresa múltiples veces para preparar la estructura dental puede producir una superficie final más lisa en la dentina que una fresa nueva. Esta rugosidad superficial modifica las características del sustrato y puede afectar la adhesión con materiales resinosos. El objetivo de este estudio fue evaluar el efecto de los múltiples usos de las fresas de diamante sobre la micro rugosidad superficial de la dentina y la resistencia adhesiva con la resina compuesta cuando se utiliza un adhesivo de autograbado. Se utilizaron fresas dentales de diamante para simular una preparación (superficie plana de la dentina) en terceros molares extraídos. Las muestras se distribuyeron en grupos según el número de usos previos de las fresas de la siguiente manera: 0, 1, 5 y 10. Se utilizaron imágenes de microscopía electrónica de barrido a ×70, ×350 y ×1000 para ilustrar la deformación de las fresas. Se midió la micro rugosidad de la dentina de cada espécimen tres veces para comparar entre los grupos experimentales y se realizó la prueba de resistencia a la adhesión por micro cizallamiento (n=15) para los grupos de 0 y 10 usos utilizando un adhesivo universal en modo de autograbado. El desgaste de los cristales de diamante y los desprendimientos fueron evidentes entre los grupos en los que las fresas se utilizaron más veces. A medida que aumentaba el número de usos, la micro rugosidad media de la superficie de la dentina disminuyó, con diferencias significativas entre los grupos de 0 y 10 usos. En las pruebas de resistencia adhesiva no se observaron diferencias estadísticas entre los grupos experimentales. Cuando se utiliza un adhesivo universal en modo de autograbado, el número de usos previos de una fresa de diamante no parece tener un efecto significativo en la resistencia de la unión dentina/resina del composite.


Subject(s)
Humans , Dentin-Bonding Agents/analysis , Shear Strength
2.
Odovtos (En línea) ; 19(2)ago. 2017.
Article in English | LILACS-Express | LILACS | ID: biblio-1506903

ABSTRACT

he present study evaluated the bond strength between glass-ceramic and resin cement, using different silane treatments, performing no previous hydrofluoric acid (HF) etching on ceramic surface, after short- and long- term storage. One hundred and eighty glass-ceramic plaques (IPS e.max CAD®) were polished and divided into six groups (n=30) to receive different silane treatments: (1) RCP-RelyX Ceramic Primer® (one-bottle silane), (2) RCP+SB-RelyX Ceramic Primer and Adper Singlebond2® (silane plus separated adhesive), (3) SBU-Scotchbond Universal® (silane-containing universal adhesive), (4) CP-Clearfil Ceramic Primer® (silane/MDP primer), (5) NC-no-silane (negative control) and (6) PC-Previous HF etching (5%, 20s) plus RelyX Ceramic Primer® (positive control). Two resin cement cylinders (Rely X Ultimate®) were built on each plaque. Each group was divided into two sub-groups to be stored for 24 hours (24h) or 6 months (6mo) in distilled water at 37°C (n=15). Then microshear (µSBS) testing was performed. Failure mode was analyzed using scanning electron microscopy (SEM). Data were statistically analyzed by two-way ANOVA and Tukey´s test (α=0.05). Both factors and their interaction resulted statistically significant (p≤0.05). PC obtained the highest µSBS values (in MPa) at both storage times (24h: 28.11±2.44; 6mo: 19.10±3.85). After 24h storage, groups RCP+SB (10.86±3.62), SBU (8.37±4.33) and CP (8.05±3.62) were not statistically different from NC (8.00±2.51); only RCP (19.73±4.63) and PC obtained higher values. After 6 months, only PC showed higher values than NC (0.04±0.01). Cohesive failure in resin cement was more prevalent for RCP-24h and PC, while adhesive failure was more frequent among all other groups. Clinical relevance: None of the commercially available silane primers tested, improve long- term ceramic/cement bonding without performing HF etching on ceramic surface. Combination of HF acid and silane, remain as a gold standard treatment for glass-ceramic materials.


ste estudio evaluó la resistencia de unión entre cerámica vítrea y cemento resinoso, utilizando diferentes tratamientos de silano, sin realizar condicionamiento previo de la cerámica con ácido fluorhídrico (HF), después de almacenamiento en corto y largo plazo. Ciento ochenta placas de cerámica (IPS e.max CAD®) fueron pulidas y divididas en 6 grupos (n=30) para ser tratadas como sigue: (1) RCPRelyX Ceramic Primer® (silano de 1 frasco), (2) RCP+SB-RelyX Ceramic Primer y Adper Singlebond2® (silano más adhesivo separado), (3) SBU-Scotchbond Universal® (adhesivo universal conteniendo silano), (4) CP-Clearfil Ceramic Primer® (primer cerámico conteniendo silano y MDP), (5) NC-ningún silano (control negativo) y (6) PC-Condicionamiento con HF previo (5%, 20s) y silano (RelyX Ceramic Primer®) (control positivo). Dos cilindros de cemento resinoso (Rely X Ultimate®) fueron construidos en cada placa. Cada grupo fue dividido en 2 sub-grupos para ser almacenados por 24 horas (24h) y 6 meses (6mo) en agua destilada a 37°C (n=15). Luego fue realizada la prueba de microcizallamiento (µSBS). El tipo de fractura fue analizado con microscopio electrónico de barrido (SEM) y los datos analizados con las pruebas estadísticas ANOVA de dos factores y Tukey (α=0.05). Ambos factores y su interacción resultaron estadísticamente significativos (p≤0.05). PC presentó los valores más altos de µSBS (MPa) para ambos tiempos de almacenamiento (24h: 28.11±2.44; 6mo: 19.10±3.85). Luego de 24h, los grupos RCP+SB (10.86±3.62), SBU (8.37±4.33) y CP (8.05±3.62) no fueron estadísticamente diferentes del grupo control negativo (NC: 8.00±2.51); sólo RCP (19.73±4.63) y PC obtuvieron resultados mayores. Después de 6 meses de almacenaje, sólo el grupo PC obtuvo valores estadísticamente mayores que NC (0.04±0.01). Fractura cohesiva en el cemento fue más prevalente para RCP-24h y PC, mientras que el tipo adhesivo fue el más frecuente para todos los demás grupos. Relevancia Clínica: Ninguno de los tratamientos de silano evaluados, mejoró significativamente la adhesión a largo plazo entre cerámica vítrea no condicionada y cemento resinoso. La combinación de HF y silano, continúa siendo el tratamiento de preferencia para cerámica vítrea durante el proceso de cementación.

SELECTION OF CITATIONS
SEARCH DETAIL